services
LIGHTNING PROTECTION COMPLETE SOLUTION SERVICES
- Lightning protection system design includes External/Structural Protection from direct effect of lightning and Internal/Power line/ Data line protection from indirect effect of lightning.
- We provide a complete system of strike termination devices, conductors, grounding electrodes, interconnecting conductors, surge protective devices, connectors or fittings.
- External Lightning protection System Design
Air Terminal Placement using the standard grid placement scheme.
-Rolling Sphere Design.
-Protective angle Method.
-Mesh Method
ESE according to NFC 17102
EARTHING COMPLETE SOLUTIO SERVICES
-ARAM is certified to work in design, calculation and installation of: • High voltage earthing • Complete earth grid infrastructure • Substations • Testing: earth resistivity testing, current injection, earth continuity.
-We work as contractors with energy authorities, government projects and construction sector including mining and rail operations. We have been involved in the electrical market since 2010 and have gained vast experience ensuring we deliver a quality service and installation package to all of our clients. We take responsibility for each project from start to finish with a focus on flexibility, project management, technical experience, safety, cost efficiency and compliance.
-Our experienced electrical grounding design staff has already provided thousands of field site designs and continue to do so on a daily basis. Since we are a tight knit group of electrical engineers with a true passion for what we do we strive to deliver excellent personal service by working closely with all our clients, regardless of the scope of the project.
SOIL RESISTIVITY MEASUREMENT
-ARAM one of the most professional companies in the Egyptian market that measured soil resistivity all cities at Egypt with many project and consultancy.
-The Winner alpha four-pin method is the most commonly used technique for soil resistivity measurements. It is performed by placing four pins at equal distance, injecting a known current on the outermost electrodes and recording the voltage between the interior
LIGHTNING PROTECTION RISK ASSESSMENT
ARAM provides comprehensive lightning risk assessments and lightning protection plans that will help to ensure that a lightning strike will not cause catastrophic failures, injuries or fatalities at equipment facilities. Our lightning risk assessment and proposed lightning protection plans illustrate the current risks and necessary steps that should be taken in order to meet the guidelines as set out in NFPA 780 and IEEE 998.